61 | Video Recorder | Q. How to test the NVR HTTP event trigger | 2023-11-06 |
A.
Test Sample Method 1. Prior to making sure NVR is on the same network as my pc 5. For example, if you want to capture an event for a particular situation with your camera and receive the result as HTTP JSON, you can set it as follows |
|||
60 | Video Recorder | Q. I upgraded to the latest version of DR-6500 series, but the Alarm-Box setting disappeared. | 2023-11-06 |
A.
A : Regards to DR-6500, |
|||
59 | Video Recorder | Q. TR-2516 Constraints. | 2023-11-06 |
A.
A : I have confirmed and shared the new TR-2516 constraints. Third-party AHD (Provision) and TVI (Hik) cameras found on Onsite do not have 4M15ips and 5M12ips options. |
|||
58 | Video Recorder | Q. I can't see the Onvif protocol on the DR-1308P. Why is that? | 2023-11-06 |
A.
A: DR-1000 series is a small form factor product and supports only IDIS cameras. Non-Onvif third-party cameras are not supported. |
|||
57 | Video Recorder | Q. PSE(PoE) Power Constraints on DR-2500 NVR | 2023-11-06 |
A.
Q : When we turn off the IR light on the bullet camera, then the Fisheye camera that turned off comes on again. The below is the PoE status with the bullet IR turned off. This is with the Bullet IR turned On
A. From products produced since June 2022, (PD69104B1) To solve the problem, |
|||
56 | Video Recorder | Q. Response of OSD button is too slow in 5MP 12.5fps of TVI camera | 2022-11-10 |
A.
A. The ADC key value entered by OSD button is read by VD Sync. In addition, to prevent malfunction due to noise, it is operated when the input value is maintained at least 2 frames. Thus, 12.5fps has a long interval VD Sync so, it works relateively slowly,
|
|||
55 | Video Recorder | Q. PoE Power Limit of NVR(DR-23xx Series) | 2022-11-08 |
A.
A. The rear PoE group MAX specifications for DR-2308/2316 products are as follows.
#1. Port 1~4 : total 37W #2. Port 5~8 : total 37W The total port is 74W and the rated usage is 50W. If over 50W is used, the 48V adapter life is not guaranteed. |
|||
54 | Video Recorder | Q. How much log is the NVR saved? | 2022-11-03 |
A.
A: IDIS NVR stores 10000 lines of log. |
|||
53 | Video Recorder | Q. How to set time on ID3916H NVR? | 2021-11-02 |
A.
On Smartguard, right click on time bar and change time. This is the correct way to set time on the product. |
|||
52 | Video Recorder | Q. How does rebuilding process of IR-300 work? | 2021-11-02 |
A.
It is done auto matically, when the faulty HDD is replaced. Please note that HDD bay should be the same and the replacement HDD should be compatible with IR-300 |
|||
51 | Video Recorder | Q. About Setup -> Display -> Main Monitor Sequence | 2021-10-29 |
A.
1. Full Sequence mode : All Channels will be switched to selected division-screen. 2. Camera Sequence mode : The selected division-screen is the reference and only one screen at the bottom(the last ch) will be switched. |
|||
50 | Video Recorder | Q. Is there any power-supply limitation to each port of recorder? | 2021-10-29 |
A.
There are no limitations or differences in each port. |
|||
49 | Video Recorder | Q. How to disable 2FA feature | 2021-07-21 |
A.
You can disable 2FA by email authentication or UPR(User Password Reset) function.
If the above two methods are not applicable, the factory reset of the NVR is required. Please contact techsupport@idisglobal.com for more information. |
|||
48 | Video Recorder | Q. Places where the logs are stored. | 2021-07-21 |
A.
- System/Debug Log in the Memory |
|||
47 | Video Recorder | Q. What does 'Out of Coder Memory' error from NVR mean? | 2021-07-20 |
A.
It means NVR memory is not enough. This can be caused when the cameras might be not compatible with the NVR. |