IR-1100

IDIS Enterprise NVR
/ NDAA Compliant
  • Pre-installed with IDIS Solution Suite VMS
  • Tested and validated with IDIS Solution Suite up to 256 Full HD H.264/H.265 IP cameras
  • Supports up to 256 Full HD cameras in real-time for enterprise-level surveillance systems
  • 1,024Mbps (128MBps) maximum recording bandwidth per server
    * Estimated performance based on NLSAS HDD measurements
  • Redundancy of power for mission-critical reliability
  • Complete compatibility with IDIS components: IP cameras, analog DVR, DirectCX TVR, DirectIP NVR, and encoders
  • Equipped with RAID 5, RAID 6 recording, Hot swappable
  • 2U rack mount chassis with sliding rails and cable management arm for ease of serviceability
  • Supports H.264, H.265 compression, and Intelligent Codec
  • Supports Onvif Profile S, Axis, Panasonic, etc.
SYSTEM
IDIS Solution SuiteCompatible with Expert and Federation
Network Connection 4 GbE RJ-45 Ports (1000Base-T)
Recording Data Rate Up to 1024Mbps (128MBps)
Number of Cameras Up to 256
Recording Storage 8 Bay
Hard Disk Drive Configuration Up to 8 x Large Form Factor Near-line SATA Hard Disk Drives, Hot-swappable, RAID 5, RAID 6
Operating System Microsoft® Embedded Windows Server 2016
Processor Intel® Xeon® Processor silver 4210 2.2G, 10C/20T
Memory8GB RAM (1 x 8GB DDR4-2666MT/s RDIMM)
Video Outputs1 VGA
MECHANICAL
Form Factor 2U Rack Mount Chassis
Dimensions (W x D x H) 482.0mm x 717.6mm x 86.8mm (18.98" x 27.71" x 3.41")
Weight34.5kg (76 lbs)
ELECTRICAL
Power Input 100-240V AC, 50/60Hz
Power Supply Redundant, Hot Swappable
Power Capacity750W
ENVIRONMENTAL
Operating Temperature 10° to 35°C (50° to 95°F)
Storage Temperature -40° to 65°C (-40° to 149°F)
Operating Humidity 10% to 80% Relative Humidity
Non-operating Humidity 5% to 95% Relative Humidity, 38.7°C (101.7°F) Maximum Wet Bulb Temperature, Non-condensing
Operating Vibration 0.26 Grms at 5 Hz to 350 Hz
Storage Vibration 1.88 Grms at 10 Hz to 500 Hz for 15 min
Operating Shock Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11ms
Storage Shock Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms
Operating Altitude 3048m (10,000ft)
Storage Altitude 12,000 m (39,370 ft)
ACCESSORIES SUPPLIED
Rack Rail SystemSliding rail system with cable management arm. Supports

• Tool-less mounting in 19”-wide EIA-310-E compliant square hole and unthreaded round-hole 4-post racks

• Tooled mounting in threaded hole 4-post racks
Cable Management Arm Yes
Rack Bezel 1, Front
Power Cord 1
CERTIFICATIONS
Emissions ClassificationFCC Rating Class A
(EMC)CISPR 22, EN55022, EN55024, FCC CFR 47, Pt 15, ICES-003, CvNS14336-1, CNS13438, GB4943, GB9254, EN 61000-3-2, EN61000-3-3
DirectivesRoHS, Reach(SVHC), WEEE
Installation environment Accessory configuration
Manual IR-1100 Quick Guide v1.0.3
A&E Specification IR-1100 A&E Specification v1.1
Brochure IR-1100